EOL: DSX-N6D6X6-60AT Expansion unit 60x6TB

Commercial Type No.: DSX-N6D6X6-60AT
Product No.: F.01U.312.362

DSX-N6D6X6-60AT Expansion unit 60x6TB
  • SAS interface-connected expansion unit with 60 internal HDDs
  • Configurable hardware-based RAID protection (RAID‑5 or RAID‑6) for highest system performance
  • Redundant hot-swappable power supplies and cooling fans
  • Fully modular design for ease of service and protected by NetApp services, including a 3 years next business day on-site support
  • Details
    Electrical requirements—expansion unit
    Parameter Low range , High range
    Nominal voltage 220 VAC , 240 VAC
    Frequency 50 to 60 Hz , 50 to 60 Hz
    Idle current 6.0 A , 6.0 A
    Maximum operating current 7.56 A , 7.56 A
    Note: cables included with the 60-bay expansion systems are designed to be used with 220 - 240 VAC power distribution units
    Power ratings—expansion unit
    KVA 1.268
    AC Watts 1222
    BTU/h 4180
    Note: for detailed information please see the latest NetApp E‑Series Storage Systems Site Preparation Guide
    System hardware specifications—expansion unit
    Chassis DE6600 controller-drive tray conforms to the 483 mm (19.0 in) rack standard
    Power supplies Dual redundant, hot pluggable
    Maximum disk drives 60 x 6 TB, 3.5”, Nearline SAS
    Maximum net capacity 307230 GB (RAID‑5 configured)
    Integrated I/O 6 Gb SAS
    Mechanical—expansion unit
    Dimensions (H x W x D)
    Drive tray 177.8 x 482.6 x 825.5 mm (7.0 x 19 x 32.5 in)
    Shipping carton 482.6 x 609.6 x 1009.7 mm (19 x 24 x 39.75 in)
    Weight
    Maximum weight 105.2 kg (232 lb)
    Maximum shipping weight 193.2 kg (426 lb)
    Space requirements
    Front—cooling 760 mm (30 in) clearance in front of the cabinet
    Rear—cooling 610 mm (24 in) clearance behind the cabinet
    Front of chassis—maintenance 760 mm (30 in) clearance in front of the cabinet
    Rear of chassis—maintenance 610 mm (24 in) clearance behind the cabinet
    Environmental—expansion unit
    Temperature
    Operating range 0 °C to +35 °C (+32 °F to +95 °F)
    Maximum rate of change 10 °C (50 °F) per hour
    Storage range -10 °C to +50 °C (+14 °F to +122 °F)
    Relative humidity (non-condensing)
    Operating range 20 to 80%
    Storage range 10 to 90%
    Acoustic noise
    Sound power (standby operation) 65 dB max
    Sound pressure (normal operation) 68 dB max

    Images

     
  • Certificates (1)
    Title Type Language
    Declaration of Conformity PDF