MBV-MKBD MBV-XKBD-* 用ライセンス、1 年

Commercial Type No.: MBV-MKBD
Product No.: F.01U.201.039

MBV-MKBD MBV-XKBD-* 用ライセンス、1 年
  • Maximum resilience to ensure continuous operation.
  • Up to 2000 cameras with a single recording server mean high savings.
  • Smart automatic stream switching for live viewing.
  • Best integration with Bosch video hardware.
  • Encrypted communication to cameras.
  • Overview
    Maximum number of workstations simultaneously viewing the same camera Multicast: 100Unicast: 5
    Supported GUI languages English, German, Dutch, Italian, Portuguese, French, Spanish, Simplified Chinese, Traditional Chinese, Russian, Hungarian, Japanese, Czech, Danish, Finnish, Greek, Norwegian, Polish, Swedish, Thai, Turkish, Korean, Arabic, and Vietnamese
    Anti-Virus software must not perform a full-scan. Performance may decrease depending on configuration.
    Event reaction time <1 second, assuming sufficient network bandwidth
    Alarm reaction time (incl. 1 live Image pane, 1 instant playback Image pane and 1 map Image pane): Maximum 2 seconds, assuming sufficient network bandwidth
    Text data Restrictions for text data written into the Logbook (this applies, if entry is stored only in Logbook, not in recordings): 10*Virtual Input (VI) with length 300 = 3000 characters: 109 items/sec (average)10 * VI data field with length 800 = 8000 characters: 22 items/sec (average)10 * VI data field with length 30 = 300 characters: 500 items/sec (average)(item = data input event) Restrictions for text data written into recordings: Bosch VMS can only process up to 3200 Bytes (corresponds to about 3200 English characters in Unicode) per event.
    Bandwidth requirements for LAN Min. 1 Gbps for connections between: Operator Client and Management Server Operator Client and VRM/DiBos Management Server and NVR/VRM/DiBos
    Bandwidth requirements for remote access >= 300kbps
    Hardware transcoder Hardware transcoder VIP-XTCXF-INT or VJT-XTCXF must be configured in VRM, refer to VRM documentation. Hardware transcoding only applicable for VRM connected BVIP cameras. For transcoding live streams it is not required that the respective camera is recording.
    Required open ports See Online Help or Manual for Configuration Client, chapter on used ports.
    Maximum number of sustained events For highest performance server: 500 events/s with Logbook 1000 events/s without Logbook 5000 events/s at peaks (within 60 minutes) with Logbook 500 events/s from ONVIF cameras
    Logbook Supported by SQL Server 2014 Express (64-bit version) 4 GB Logbook size
    Maximum number of Task Schedules 200
    Management Server Redundancy (VMware) Available with VMware HA. Please contact Bosch Design Engineer for redundancy solutions.The following software versions are used: ESXi Server 5.1.0 U1 build 1065491 vCenter Server 5.1.0 U1 build 1064983 Required hardware 2x HP ProLiant DL380 PCs with 8 GB RAM and 1x 4-port NIC (one DLxxx for each ESXi server). 1x HP ProLiant DL380 PC with 8 GB RAM (for Control computer with monitoring) Not necessary if Control computer is installed on ESXi server as virtual machine. Note: For configuration, only a workstation is required. 1x Bosch DSA E-Series. For use with VMware you must install the default NetApp firmware on a DSA E-Series device. The firmware and the manual are available in the Product Catalog of Bosch VMS (Software & Support). Required VMware licenses/Windows licenses 1x VCS-FND-C VMware vCenter Server 5 Foundation for vSphere up to maximum 3 hosts. SNS is required. 1x VCS-FND-G-SSS-C Basic Support/Subscription for vCenter Server 5 Foundation for vSphere for 1 year. 2x VS4-ADV-C VMware vSphere 5 Advanced for 1 processor (maximum 12 cores per processor). SNS is required. Included: vShield Zones, Data Recovery, Fault Tolerance, Hot Add, vMotion, Thin Provisioning, High Availability, Update Manager, VCB / Storage APIs, VC Agent, 4-way vSMP, VMware ESXi or VMware ESX, 12 Physical Cores/CPU, 256GB Physical Memory. 2x VS4-ADV-G-SSS-C Basic Support/Subscription for VMware vSphere. Advanced for 1 processor for 1 year. If current hardware is used, the following licenses must be ordered additionally: 1x Windows license for: Windows Server 2008 R2 (64 Bit) for control computer and ESXi server. 3x licenses for 2nd CPU
    Management Server Disaster Recovery (Hyper-V Replica) Hyper-V from Microsoft OS requirement: Windows Server 2012 SR2 (64-bit) Minimum hardware requirements:2 HP ProLiant DL380 PCs with 16 GB RAM and 1x 4-port NIC, 200 GB hard disk
    Management Server High Availability (Hyper-V Failover Cluster and Starwind) Hyper-V from Microsoft; OS requirement:Windows Server 2012 SR2 (64-bit) with Domain Controller for HA Minimum hardware requirements:2 HP ProLiant DL380 PCs with 16 GB RAM and 1x 4-port NIC Shared storage for HA: Tested with NetApp DSA E-Series 2600 with 2 controllers
    Version 3.60Previous versions are not supported.
    Maximum count of VRM servers per Management Server 125 (maximum 2000 Cameras in total)
    Maximum data rate per iSCSI Please contact Bosch Design Engineer for iSCSI storage solutions.
    Max. number of playback sessions 64
    Operating System Windows 8.1 (64-bit, Professional or Enterprise)Windows 10 (64-bit, Professional or Enterprise, patched with Anniversary Update)We recommend installing Internet Explorer 11.
    CPU Intel Core i7 4770 3.4 GHz (up to 3.9 GHz)
    RAM Minimum 8 GB
    Free disk space Minimum 3 GB for Single Site Systems Minimum 5 GB for Enterprise Systems We recommend having minimum 15% free disk space.
    Network card 1000Base-T
    Display Resolution Minimum per monitor 1024x7681280x1024 or higher recommended
    Recommended Graphic Cards MHW-AWGC-K2200 MHW-AWGC-K620 MHW-AWGC-K4200 MHW-AWGC-K5200
    Operating System Windows 2012 Server R2 (64-bit) or Windows 2008 Server R2 SP1 (64-bit) required for > 500 cameras Windows 8.1 (64-bit) required for Management Server, Configuration Client and Operator Client on the same computer, and maximum 500 IP cameras/encoders We recommend installing Internet Explorer 11.
    CPU Intel Core i7 4770 3.4 GHz (up to 3.9 GHz)
    RAM Minimum 8 GB
    Free disk space Minimum 15 GB We recommend having minimum 15% free disk space.
    Network card 1000Base-T
    Display Resolution 1280 x 1024
    Operating System Windows Server 2008 R2 (Standard Edition, 64-bit), Windows Storage Server 2008 R2 (Standard Edition, 64-bit), Windows 7 Ultimate, Professional (SP1, 32-bit, 64-bit), Windows Server 2012R2, Windows Storage Server 2012R2
    CPU 1x or 2x Quad-Core Intel Xeon Processor E5606 (2.13 GHz, 8 MB L3 cache) or faster
    RAM Minimum 4 GB
    Free disk space 1000 MB We recommend having minimum 15% free disk space.
    Network card 1 Gbps
    Display Resolution 1024x768 or higher
    Link to App Store www.boschsecurity.com/MobileVideoService
    Maximum number of Mobile Video Service instances per Management Server 5
    Number of simultaneous connections per Mobile Video Service (1 mobile device consumes 1 connection, each stream consumes another connection) up to 20
    Supported cameras IP cameras with H.264 or H.263 support that are controlled by Bosch VMS (not controlled by VIDOS) ONVIF cameras BRS/DiBos/DVR cameras
    iOS Version for iPhone/iPad 7.1 / 8.3 / 9.0.2 / 9.3.5 / 10.0.1
    Hardware version iPad iPad, iPad 2, iPad 3rd generation
    Hardware version iPhone iPhone 4, iPhone 4S, iPhone 5C
    Browser (Web Client) Internet Explorer 11.0.96, Firefox 45.0.2, Chrome 50.0.2661
    Intrusion panels from Bosch For use with Bosch VMS, the Automation Device in the intrusion panels must be configured as Mode 2. G-Series US1A: B9512G (required firmware version: 3.03.14) B8512G (required firmware version: 3.03.14) B-Series US1B: B5512 (required firmware version: 3.03.14) B4512 (required firmware version: 3.03.14) B3512 (required firmware version: 3.03.14) GV4 panels (not supported if Microsoft Windows patch 3155464 has been applied to the system): D9412GV4 (required firmware version: 2.03.018) D7412GV4 (required firmware version: 2.03.018)
    Barco Monitor WallTransform N Series Barco RCPPlus-Agent 0.9.0.7
    Analog Matrix Switch Bosch Allegiant series, firmware 8.75 or later and Master Control Software version 2.94
    Bosch POS/ATM Bridge Version 1.10.00.12(63029)/2010-9-10
    CCTV Keyboard KBD-Universal XF keyboard (USB keyboard) Bosch IntuiKey keyboard, firmware version 1.96
    Digital I/O Digital I/O Advantech ADAM-6050, ADAM-6052, ADAM-6060, ADAM-6066
    Digital Video Recorders DVR 431, 440, 451, 480, 630, 650, 670, 700 series (maximum 50 managed DVRs per Management Server) Bosch Recording Station 8.10, 8.11 DIVAR AN 3000 / 5000 DIVAR hybrid 3000 / 5000 DIVAR network 3000 / 5000 DiBos, firmware version 8.7 Maximum 100 BRS/DiBos recorders per Management Server
    USB to Serial adapter Belkin serial adapter cable F5U103vea
    Ethernet to Serial adapter Comtrol DeviceMaster RTS 4-Port
    BVIP Devices DINION IP starlight 6000 HD, DINION IP starlight 7000 HD, FLEXIDOME IP starlight 6000 VR, and FLEXIDOME IP starlight 7000 VR FLEXIDOME IP panoramic 5000/7000 FLEXIDOME and DINION 2000/4000/5000/7000/8000/9000 cameras series AUTODOME IP 7000/5000/4000 EXTEGRA IP 9000; MIC 7000 with VIDEOJET 7000 (supporting alarm inputs, and outputs, audio, washer relay, local recording and playback); MIC 612/550 MIC 550, 612, MIC7000 cameras with VIDEOJET connect 7000 (supporting alarm inputs and outputs, audio, washer relay, local recording, and playback) H.264 Series encoders and cameras MPEG-4, H.264 Main Profile, H.264 Baseline Plus are supported (H.264 Baseline and MPEG-2 are not supported) VIP-X Series encoders and cameras Decoder: VIDEOJET decoder 3000/7000 VIDEOJET decoder 8000 (supports 4K ultra HD cameras on Monitor Wall) VIP XD HD VIP XD
    ONVIF cameras Maximum 2000 ONVIF camerasSupported cameras are listed on the Bosch Integration Partner Program website. For non-listed cameras refer to MBV-3RD PRTY
    Unmanaged sites Maximum 9999 unmanaged sites. Supported unmanaged devices: Bosch VMS, DIVAR IP 3000/7000, DVR 431, 440, 451, 480, 630, 650, 670, 700 series, DIVAR AN 3000, DIVAR AN 5000, DIVAR hybrid 3000 / 5000 DIVAR network 3000 / 5000, BVIP devices Maximum 5 DVR/DIVAR AN devices per site
    Connectivity with Building Integration System Version 4.2 / 4.3
    Foyer Card Readers Maximum 2 readers per Management Server are supported. MINITER 485 is supported.
    DTP 3N Box Allows for connecting maximum 4 ATM devices to your Management Server.
    Audio devices Supported audio formats: G.711 L16
    VRM Live, playback, PTZ control
    ONVIF Live, playback, PTZ control (all via VSG)
    Local Storage Live, PTZ control
    Live Only Live, PTZ control
    BRS/DiBos Not possible
    DVR Live, playback, PTZ control

    Images

     

    Features

    BoschVideoIntegration HD4K ITCompatibility Openness3rdParty Resilience24-7